LNX LPX Chromel Copel High Temperture High precision Type L Thermocouple Extension Bare Wire Class 1
TYPE L (CHROMEL vs Copel) may be used in oxidizing, inert or dry reducing atmospheres, or for short periods of time under vacuum. Must be protected from sulfurous and marginally oxidizing atmospheres. Produces the highest EMF per degree o any standardized thermocouple.
1. Chemical Composition
Material | Chemical composition (%) | ||||
Ni | Cr | Cu | Mn | Al | |
LP(Chromel) | 90 | 10 | |||
LN(Copel) | 44 | Bal | 0.5-1 |
2. Physical properties and Mechnical properties
Material |
Density(g/cm3) |
Melting pointºC) |
Tensile Strength(Mpa) |
Volume resistivity(μΩ.cm) |
Elongation rate (%) |
LP(Chromel) | 8.5 | 1427 | >490 | 70.6(20ºC) | >25 |
LN(Copel) | 8.8 | 1220 | >390 | 49.0(20ºC) | >25 |
3. EMF Value range at different temperature
Material | EMF value Vs Pt(mV) | ||||
100ºC | 200ºC | 300ºC | 400ºC | 500ºC | |
LP(Chromel) |
6.750~6.970 |
14.436~14.678 |
22.711~22.967 |
31.348~31.628 |
40.116~40.468 |
LN(Copel) |
EMF value Vs Pt(μV) | ||||
600ºC | 700ºC | 800ºC | 1000ºC | 1100ºC |
48.887~49.309 | 57.612~58.100 | 66.200~66.738 |